Device missing channel ae2. It isn't a huge problem but it is an annoyance. Device missing channel ae2

 
 It isn't a huge problem but it is an annoyanceDevice missing channel ae2 Playing on FTB Infinity

It is a multiblock structure that must have the form of a cuboid without any holes and may consist of the following blocks, all built from Crafting Units : at least one storage, for example 1k Crafting Storage. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. The device that is working and the device that isn't are on the same branch of cable. As already mentioned above, most AE2 devices need a channel to work. ago. I tried to set the channelmode to infinite but then it still says "device missing channel" and the ME System freezes. Creating this device is extremely expensive due to it requiring a Quantum Link Chamber in the center, and eight Quantum Field Rings around it. Some help. This article is about ME Controller from Applied Energistics 2 . Business, Economics, and Finance. The command is /ae2 channelmode <mode> to change. Please help! I have a dense cable going from my controller, to a bunch of machines that are used for autocrafting. is the Fools one, which is about 7 idle days of waiting. I have my ME system set up in single player and it all works fine, I'm no stranger to AE2. I didnt recognize the vibration chamber. Some parts of it work perfectly with no trouble. Translated into Japanese. Wiring has its own simple concepts that go along with this channel system: 0. I am not sure my controller setup is right. It was more of a does anyone know if AE2 has. deepcage, Aug 19, 2019 #5. Update the headphones using your computer to the latest firmware manually. Unfortunately, it just says device missing channel. Also, you have to connect each sixpack to the cable of the previous module with a quartz cable. Official AE2 page on P2P tunnels. Disable "handsfree telephony". The main dense cable they are connected to is taking 5 channels from the terminals and crafting CPU on the left as shown in screenshots. cable_bus. P2P can only be connected to the me controller face or a cable directly connected to the controller. Find your headphones and double click them. OR: If your device supports Near Field Communications (NFC): 1. shadowfactsdev. 이렇게 채널을 잃어버린 장치들은 정상작동하지 않으며, 'Device Missing Channel'이라고 표시됩니다. It'll happily route 13 things through an interface and have 5 missing channels even if it has another longer path through a dense cable. Again any help is just great! run: Minecraft Version: 1. The device that is working and the device that isn't are on the same branch of cable. I tried in singleplayer too, same thing happens, but with a different amount of devices. At minimum, you'll need a Controller, a Crafter, a Pattern Grid, some Patterns and some storage. So I have a setup with a dense cable coming from a controller into a p2p tunnel. Follow these steps: a) Press the ‘ Windows + W ’ key on the keyboard. You can use RS fine, you just need to make the fluix crystals and such first. ME Pattern Provider. My issue is this: when I attach a Smart Cable to something down the line, it says "Device Missing Channel", however, the. I'll try and find the ep for a practical demonstration. I'm having an issue with my network where my import buses are saying "Device Missing Channel"…P2P Tunnel. Smart, covered, or normal ME cable = 8 channels carrying capacity. [Feedthebeast] AE2 - Device Missing Channel - Doit casser le contrôleur ME et le remplacer pour le réparer. I built a nuclear power plant and wants automate it with a cyanite reprocessor but now my fluix cables do not transport the Blutonium to the reactor and the Cyanite. cfg" and open -> Find the following ->. Patterns can be placed inside the ME Interface in order to facilitate auto. The ME Controller is a block added by Applied Energistics 2. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Shows load similarly to ME Smart Cable, with each line lit. 5. Power input is limited to network capacity/tick, regardless of input. . Here the full setup : Development. But the bus will always say missing channel. Probably just 8. Storage, 1-32 depending on how much you want to store. Yes, jus to go the . Jun 23, 2019 Go To Latest Post. You can't have more than 1 controller on a network, but adjacent controllers form a multiblock, allowing more sides. I could be wrong about that, though. 2. Also see Spatial IO Compat Project. The ME Export Bus is a transparent block added by Applied Energistics 2. b) Type troubleshooter in the search box and then press enter. The other day the exporters stopped working and are now saying device missing channel. Mar 31, 2017. Make some Patterns and put them in the pattern slot as illustrated. Device Missing Channel . Devices connected to the same network can communicate and interact with each other, and the channel system limits the number of devices that can be connected to a single cable, adding a layer of planning and. It needs to have power, whether it be from connecting to an me system or just a power converter. CryptoThe ME import bus (added by Applied Energistics) is the opposite of the ME export bus, and allows you to take items from external sources such as chests and furnaces and import them into the ME network if storage is available. This component stores ME Encoded Pattern inside of it, they can either be loaded before completing the ME Molecular Assembler Chamber, or afterwards. Im currently using a 5x5 (25) wall of ME drives connected with dense cables and it says on 2 of the drives that it has a "channel missing" have tried to downsize to a 4x5 (20) and it still has the same message on 2 drives, ive tried using glass cables, smart cables, and now dense smart cables. A controller can power 32 devices from one face, but a normal ME cable only has space in it to carry 8. Closed Novasae opened this issue Feb 22, 2015 · 2 comments. Channels config set to false Tested with 6 drives (full) and ME Terminal, no issues Tested with 7 drives (full) and ME Crafting terminal, intermittent issues Tested with 8 drives (full) and ME Crafting terminal, one of the drives, mostly at random between interacting with the ME crafting terminal would not show. Glass, Covered and Smart cables all support 8 channels. I am new to AE2 and struggling a bit with some of the set up. This allows you to connect channels from that dense cable and, since you can have multiple outputs with P2P tunnels, you could always hook up 16 P2P outputs and use those 32 channels sparingly. Port Channel Group is a set of multiple physical Ethernet ports aggregated together for the purposes of increased aggregate throughput and/or for improved network resiliency. I believe I have enough room for more channels, as I only have 3/8 channels on the cable, but the the furthest import bus on my cable gets "Device Missing Channel" whenever I connect it. It's on Also my ds18b20 is getting no…So I was setting up automation for AE2 components when i came across a problem with the channels, on the import buses one always says "Device missing channel" and I have switched cables to dense cables behind and I cannot seem to fix it when i remove an interface behind one of the inscribers the import buses find their channels, looking at the. All AE2 micro-block devices show a when channel active or no channel available. ago. Pack is FTB revelation 3. Newcomer to AE2 here. CryptoSaved searches Use saved searches to filter your results more quicklyPut it into a Charger to recharge it. Each Spatial Pylon Multiblock requires a channel ( 1 per strand of blocks, not 1 per Spatial Pylon ) to function. Tunnels are 1 input to N outputs. Opening the Pattern Generator. You'll end up with a controller conflict, and the whole thing will be inoperable. The P2P Tunnel for ME, for instance, passes through channels. From the AE2 web site: Dense Cable Higher Capacity cable, can carry 32 channels unlike standard cable which can only carry 8, however it doesn't support buses so you must first step down from dense to a smaller cable (such as ME Glass Cable or ME Smart Cable) before using buses or panels. Devices go offline when ME Quantium Link online #1664. 그래서 우리는 더 많은 채널을 사용하기 위해 우리는 'ME Controller'라는 장치를 사용할 수 있습니다. (For instance Import/Export/Storage Buses, ME Drives or Chests, P2P Tunnels, etc. If the ME controller hub is working fine, then attached your p2p to one face first of the hub thats powered and the other p2p to the location. Each subnetwork of 6 drives, ME Interface and ME Storage bus form an ad-hoc network without a controller. Meaning they don't touch your normal network. ME Controllers output 32 channels per side. Put a piece of Oak Wood in the crafting grid. Change the interface thats on the bottom on the 4th image. The way I connect my network is using dense smart cables so I can carry more channels and keep track of. Done. Use a quartz cable to connect the smart cable to the ME controller hub, the huge one and remove the intermediate controller. CryptoQuick note, sticking the Cell into a crafting grid when it has no Items stored as data will also work to extract the component. In the Sound window, click or tap the Recording tab. It has 8 channels. AE2 Molecular Assemblers not working. I have an issue with my ME Storage system with AE2. by ItsMeCryptic. You might poke around using this device on your networks and verify that the system returns the devices that are physically there. Relatedly, don't have a controller on both sides of the bridge. Each block will use 10 + distance 2 AE/t (configurable)Search results for 'device' Search. ae2. Craft a Blank Pattern and encode it with the desired recipe in a ME Pattern Terminal. Otherwise, if no channel is left, it stays pink and you see "Device Offline". If you don’t want it using channels on your me system you can attatch it to the system with quartz fiber, which moves ae2 energy but not. AE2 Version: 1. I tried removing one interface, and it worked again, placing anything requiring a channel, turned the whole system offline. 105 Points. LitrosNub. Nothing I've tried fixes the issue. If you input too much power into the network so they fill up near-instantly as you approach, use a TE cell, EIO capacitor or similar device to throttle your input. 7. not sure what else to try or what I should do. Channel Modes . 1 Definitions and conceptual implications . This setup is fine. Not sure which episode of Direwolf20's Let's Play season 7, but an all AE2 method can be used. 9. Business, Economics, and Finance. If you mean in the game, using an ME controller with dense cable will increase your channels from 8 to 32 per side of the controller. Input P2P ME Tunnel Online After Breaking Cable. 📦 Buy replacement earphone cables line with free shipping and free return online. Ok, so channels are what are used to transfer data in AE2. Channels. More often than not, most headphone faults can be traced back to software issues. The P2P network will transfer power, but won't use power it's transfering. CryptoI set up my first ME controller with ME Drive "with 64k storage cell inside" everything seems to have power and I'm using Dense Smart Cables to connect a Crafting terminal to it. ae2. When I open the. 566. I just like to smack them on any dense cable with spare channels. This mod adds only one block, an "ME Capability Adapter", it basically allows Applied Energistics connections over things that proxies capabilities, such as Compact Machines 3 Tunnels. The broadcasting. On the right click devices and printers. 12. (The controller doesn't handle data. I've just started playing Omnifacotry which has channels turned off by default. TY. Every machine in AE2 takes up 1 channel. We try to simplify complicated matter so that everyone can enjoy the mods being shown. 1. • 6 yr. For now i just want my storage drawers to be reconnected to my new network so i have access to my millions of ressources. Each face of an ME Controller multiblock can support up to 32 channels. 9. Other factors such as poor I/O response time, high paging rates. My ME interfaces say "device missing channel" when I am only using 23/32 channels. 7 Are there max channel per a controller? I have enough power but some random ae elements missing channel. One of the many reasons I don't like ae2 very much, but this pack doesn't have refined so I'm stuck with it. Also it's. I've added a new block to AE2 Stuff 0. Then hover over it, it should say YOUR name on the top (Bio. If you need support for your product or assistance with troubleshooting, check out Bose Support and browse articles on your specific product to learn more. This alpha version introduces new options to change how AE2 channels behave in your world. Reply reply defakto227. Also, a Network Visualization Tool will help diagnose similar issues, and let you see Channel routing visually all over your network, it's a. I believe channels are configurable in the config, including disabling channels all together and have a free form build. Shop fishing line trimmer with free shipping and free return. ago. Suppose you have 32 channels going into a P2P tunnel, you can pass those channels to another point on your network. Bobbanethelord • 3 yr. 1: 945 AE2 stuff crash while launching (stone block) >>Business, Economics, and Finance. 17 and newer, head to the new website. I tried to set the channelmode to infinite but then it still says "device missing channel" and the ME System freezes. It only requires you to use AE2 items in the recipe for RS items, so it's not unlocked too early if you drop the mod in. Your device may ask you to accept pairing. Software Solutions for When One Side of Bose Headphones Isn’t Working. An import bus takes a channel, a disk drive takes a channel, a terminal takes a channel, every machine takes up just one channel. The face that you can see on the front has to touch a machine or cable. Nuances of channel-less AE2. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. anabsolutesloth • 4 yr. As all cables except dense cables only can. At my base I have a Quantum Link with a Blue Dense cable coming directly from an ME controller attached to the top of it. Place an empty bucket into the input slot (square with arrows pointing to its center), and the bucket will be filled with the selected liquid and moved to the output slot (square with arrows pointing away from its center). Redstone P2P can be useful to replace vanilla redstone wire. Can you use it? ja_jp. AE2 - P2P Tunnels Tutorial. I believe I have enough room for more channels, as I only have 3/8 channels on the cable, but the the furthest import bus on my cable gets "Device Missing Channel" whenever I connect it. The mod includes a network-based storage sy. by animmale1. Bose QuietComfort Earbuds II. What I don't understand is when I try running a dense cable for my p2p tunnels, I still hit that 8 p2p tunnel devices limit. The power tunnels (like FE) let you transfer power through your ME system and thus don't to run separate power cables, but there is a 5% power tax based on the input. Next, each multiblock pylon you form requires one channel. Of course, then you get more complicated stuff like the P2P tunnels, but it's better if you just understand regular. It is the thing that executes autocrafting tasks. Devices connected to the same network can communicate and interact with each other, and the channel system limits the number of devices that can be connected to a single cable, adding a layer of planning and. I think there's also Light, Item, and Fluid P2Ps but they seem more situational. Hello all, I've been feeling like I've potentially been missing an encoding setting. it doesn't tend to backtrack. Considering each Tunnel requires its own channel that might not sound amazing, but you can sub-network stuff with AE2 so those channels don't actually matter. The interfaces also transfer channels and the algorithm that determines what channel gets used for what is kinda terrible. A dense wire can carry all 32. Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return. Once this is done, restart the computer and check the status. The. And that ae2 will take the shortest path to the controller for stuff that needs channels, even if that path is through an interface that can only transmit 8 channels (7 + the interface) through it. ago. Again. It is the heart of ME Networks and is used to provide more channels to the network. Hello, so I've been building a sugar cane farm so that when the cane grows by 1 it gets sucked up with the annihilation plane to suck it up. I have this tower a few blocks away from my controller and will be copying. Do you happen to know what it says when it says device missing channel? I took off the oxy gear and that's what it says when hovering over the pattern provider. . Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return. Ok, so channels are what are used to transfer data in AE2. This episode is all about taking your AE2 game to the next level. ie controller > 8 or 32 channel main cable > 8c. 7, just about everything you used to know about it is now different, and there's new mechanics that need addressing. See pic number 2 & 3. Use a quartz cable to connect the smart cable to the ME controller hub, the huge one and remove the intermediate controller. Autocrafting, first choices are AE2 or Refined Storage. Forum Threads (11) 1; 2; Next; Topic Latest Post Replies Views; BarXStop Reviews: Most Effective and Safe Training Device on the Market >> by animmale1 Nov 1, 2022. Read about channel in AE2 before you build anything. ) Things like ME Controllers, Inscribers or Crystal Growth Accelerators, do not use channels. The barrier to entry for AE2 is terrible. ME Capability Adapter. Real quick question about ae2 Why do I have to break a cable and replace it in order for the message "Device missing channel" to change to "Device online" or I don't and I just need to wait(10-15 secs) for it to update. Properties. xml file created by the OCT does list the shared computer and device based activation entries in it. Add a Comment. Here is an imgur album I created (contains screenshots):. ruifung added the bug label on Sep 23, 2015. ae2. Ah, read through some more threads after messing with it on my own and was directed to the AE2 wiki, and it does indeed look like you cannot nest P2P Tunnels: "However with the great flex-ability they give you comes a limitation, the channel of a p2p tunnel cannot be carried by another p2p tunnel, meaning that you cannot nest them recursively. Each device takes one channel. Closed Quantum Network Bridge Channel Limit? #1644. This can be tricky if you are changing after you have already started the world, I admit. The Subnetwork with the P2P Channels needs it's own controller becauae it uses more than 8 channels, also the P2P tunnel next to the terminal is facing the wrong way. When you've connected your pylons to your Spatial IO Port, if everything is cabled correctly, after a short calculation period you should see an efficiency number. Networking and Channels: AE2 adds a whole new level of strategy to your Minecraft builds with its networking and channel system. It isn't a huge problem but it is an annoyance. I did notice that the . Fourth - there should be a channel being used on your P2P "service" network for each connected P2P device (assuming none of them are pointing the wrong way) as the P2P service networks rarely include a ME controller this means they max out at 8 P2P tunnel devices - for between 4 and 7 tunnels depending on how they are linked. But from what it sounds like, a single sense cable should let it work. but the last Dropper (far right) is not hooked up. Why is the device missing channel ? (AE2 1. If. 0. Only useful when used in conjunction with a Spatial IO Port, All Spatial Pylon in an ME Network are part of the came SCS. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. forge-1. AE2: Matters a lot! All devices uses channels and cables/controllers/whatever only have so many channels. Перевод "channel" на русский. •. I have tried without ME conduits but with regular cable to no avail. Vote. The Export Bus must be configured with items in its GUI to export it; leaving the configuration blank will result in nothing being moved. ChunkLoggerOff=チャンクロギングがオフになりました commands. Again. Your ME Drive is showing an orange indicator, which means it's run out of room for new types. 10. Ultrasonic correction sensor is used in photoelectric products for a high level of security. An AE2 ME Terminal is emitting light when active. This is the functional opposite of the ME Export Bus. Environment: The ME Controller outputs 32 channels per side. Unlike the ME Chest, the items that are stored inside the storage cells cannot be directly accessed; instead the drive must be connected to a ME Network which allows. MCDylanf3. Coming from AE1 the changes feel pretty severe going from the big fire and forget network to this much more micro managed style. Im trying to automate a lot of my AE2 system, but I'm running into a problem with one of my import buses. Also worth noting that just a 1K fluid cell can hold over 8000 buckets of a fluid if its partioned. Think of them as individual cables within the wires you use. For Minecraft 1. If you disconnect the back cables, they will still show up as device online, even though they should show up as device missing channel: If you make the towers stop touching, it will go back to working fine, but its still not how it should work. P2P Tunnel or "Point to Point Tunnels" are a versatile configurable system to move items / redstone / power / and fluids from one location to another though an existing ME Network without storage. The ME Import Bus requires a channel to function. Plug the QC 35 II into a wall charger for at least 5 seconds, then remove the cable. p5k likes this. The ME Export Bus will try to export any of the items. I'm guessing the purple cable had 7 used before connecting to the assembler. Today we are looking at Applied Energistics 2 an. An import bus takes a channel, a disk drive takes a channel, a terminal takes a channel, every machine takes up just one channel. Fourth - there should be a channel being used on your P2P "service" network for each connected P2P device (assuming none of them are pointing the wrong way) as the P2P service networks rarely include a ME controller this means they max out at 8 P2P tunnel devices - for between 4 and 7 tunnels depending on how they are linked. CryptoCheap Generator Parts & Accessories, Buy Quality Home Improvement Directly from China Suppliers:GV13T 220V AC Digital LED Display Generator Instrument Voltage HZ Timer Meter Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return. Different devices can be connected to the ME Network, such as an ME Drive, for the. On the right click devices and printers. Any device that can access or move stored items requires a channel. Rest of the video is a more in-depth demonstration of how they work, and how to design with them in mind. r/feedthebeast. There's smart versions of both cables to tell you how many channels are being used. • 2 yr. So I was setting up automation for AE2 components when i came across a problem with the channels, on the import buses one always says "Device missing channel" and I have switched cables to dense cables behind and I cannot seem to fix it when i remove an interface behind one of the inscribers the import buses find. Controllers, dense, and smart cables are only useful in the context of showing channel details. AE2 Device Missing Channel. Additional context. Use iOS Settings. This allows 8 levels of this same checkered pattern for a total of 32 channels in a tower of 8 levels. 74b137. 4 Subordination: Respect My AuthoriTAY . newcomer to AE2. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Each ME Drive requires a channel, and glass cables only carry 8. A multifunctional button that instantly enhances confidence, adds power and acoustic to any vehicle. AE2 Channel Bug Testing. Dense cables = 32 channel carrying capacity along the line. #2. 3. I am not experienced with the United Airlines App, but this fix works for Windows interactions! On my end, There is a driver for "Bose AE2 Soundlink Hands-Free. well then I guess you don't want to get your system working. Just FYI: The Crystal Growth Accelerator doesn't get any power, because it has a wrong orientation. Any suggestions?Business, Economics, and Finance. I have 3 main Smart Cables going into a Dense Energy Cell, and the three have channel values as follows:. cell_workbench. 16. AE2 Channel Issue . Dense Cables, Quantum Network Bridges, and ME P2P Tunnels can transfer 32 channels each. The ME P2P Tunnel is a block added by the Applied Energistics mod. An updated follow-up video about dedicated P2P tunnel networks. Each face. B. The wireless connector from AE2 Stuff also has problems with not transferring signal always. Hello, i have a problem with my ae2 sytem. jar. Первый канал называется канал запросов или наземный, второй - канал ответов или спутниковый. Disk storage is setup to be quantity-focused so is best for systems with high item counts but few differing types. It is not possible to have 2 ME Controllers in one ME Network, though a multiblock structure can be created. Attach a P2P output to that and have a Dense cable come out the other side. Business, Economics, and Finance. The network will continue to do this until I break and replace the cable on the other side of the Input ME P2P Tunnel. AE2 needs an easier way to find devices which are missing channels. Before you can use the Bluetooth for bose headphones, you need to ensure the device list is ‘paired’ with the headphones do this with a pair of Bose headphone you have two choices: Download Bose Connect. Some help. Solution 6: Update Bose Connect Check for and install available updates. ago. Below you can see the ME Terminal with a blue rectangle on its back connector, because it has an active channel. For each Child Interface that is not 'up up', follow the steps in the Resolution Guide - EX. A network can have any number of ME Wireless Access Point with any number of Wireless Boosters in each one, allowing you to optimize power usage and range by altering your setup. I'd recommend building a dedicated Big Reactor with a layout similar to this when you can afford it. Forge Version: 14. 8 in normal cables. The dense cable indicates 4 channels are used, so I don't know why I'm unable to add additional p2p tunnel devices. I am supplying the Molecular Assembler's proper power and channels, they have the recipe, and there are crafting processors. 0: 4,265 Project Ozone 3 AE2 facades missing >> by pyroblaze202 Jun 23, 2019. Business, Economics, and Finance. The command is /ae2 channelmode <mode> to. I have a ton of ME Storage Busses attached to barrels, but, after a certain amount they started to show the “Device Missing Channel” message. 한 네트워크에 장치를 8개밖에 못 쓴다니, 말도 안되죠. newcomer to AE2. If you think that that would be a challenge then that just means the mod is not for you as AE2 is so much more than a simple storage mod - go with iron-chests or whatever. The 1. Newcomer to AE2 here. Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return. 한 네트워크에 장치를 8개밖에 못 쓴다니, 말도 안되죠. If your headphones now appear, right-click them and select Enable. Like I showed in the video (I hope the audio stayed but I'm not sure) the smart cable shows that I'm only using 5 of 8 channels, so I should have more than enough. well then I guess you don't want to get your system working. Bose Smart Soundbar 900. AyeItsKatieMC Well-Known Member. In the setup with seven machines, using the main network would require 18 channels (7 interfaces, 7 import buses) if you were just to use AE2. Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return. ae2. 2 Steve's First Network . Первый канал называется канал запросов или наземный, второй - канал ответов или спутниковый. Once and a while, when the energy cells are fully charged, my ME Drive looses power for a couple of minutes and everything says Device Missing Channel, but then eventually power is restored. When I go to add another export /import bus, they show as "Device missing channel" and sometimes still function, but oftentimes not until I reset the network, then they're fine as well. . ae2. 0 alpha that provides wireless connections. Controller, crafting-terminal, 1-2 drives and some disks. Once and a while, when the energy cells are fully charged, my ME Drive looses power for a couple of minutes and everything says Device Missing Channel, but then eventually power is restored. #2. Registered members Current visitors New profile posts Search profile postsNeed help with AE2 in Enigmatica 2: Expert. I have a ton of ME Storage Busses attached to barrels, but, after a certain amount they started to show the “Device Missing Channel” message. But honestly, i wouldn't reccomend doing it. No branches or pull requests. Playing on FTB Infinity. Devices connected to the same network can communicate and interact with each other, and the channel system limits the number of devices that can be connected to a single cable, adding a layer of planning and. The ME Dense Cable is the only cable that can support 32 channel simultaneously so it can be used as a main data line to connect to another ME Controller or branch off into 8 channel distribution lines via ME Glass Cable, ME.